Assertion

AssertionId
RAD68-037 Testable
predicate
XDSDocumentEntry Attribute: uniqueIdShall be the same as the SOP Instance UID of the corresponding DICOM KOS object. In the event that any information in the manifest changes and it needs to be resubmitted from the Imaging Document Source to the Document Repository, the Imaging Document Source shall generate a new SOP Instance UID for the DICOM KOS object.
Prescription level
Mandatory / Required / Shall
Page
179
Section
4.68.4.1.2.3.2
Status
reviewed
Last changed
2/13/17 11:48:15 AM by aberge
Comment

Applies to

Audit Messages

Integration Profiles

Transactions

Standards

Covered by

Rules

MBV

Covered by (Deprecated)

Tests

Test Steps

Rules

Document name
Provenance
Revision
Action
IHE Radiology Technical Framework - Volume 3IHE14.0