Search Criteria : 6 assertions found for this search Review filtered assertions

Assertion

Applies to

Applied to
Not applied to

Coverage

Covered by
Not covered by
Id scheme
Assertion id
Status
Testable?
#Coverage
#Applies to
Comment
Predicate
Page
Tags
Last changed
Actions
LAB27LAB27-001validatedTestable 0 5 After the Analyzer working in query mode recognizes one or more specimens, the Analyzer sends a WOS Query Message (QBP^Q11^QBP_Q11) for each specimen to the Analyzer Manager.168Section 3.Q.53/7/16 2:23:29 PM by mpattillo
LAB27LAB27-005validatedTestable 0 1 An analyzer supporting the "Query All" Option SHALL be capable of sending a query for all pending work by using the query name WOS_ALL in field QPD-1. The only fields populated in the QPD segment SHALL be QPD-1 and QPD-2. 171Section 3.Q.5.43/7/16 2:23:29 PM by mpattillo
LAB27LAB27-006validatedTestable 0 1 An analyzer supporting the "Query by Rack" Option SHALL be capable of sending a query identifying the position of the specimen in the rack (carrier). The only fields populated in the QPD segment SHALL be QPD-1 and QPD-2, QPD-4, QPD-5 and QPD-8. The first four are Mandatory, the latter is Required if Available. QPD-4 identifies the rack and QPD-5 is the position in the rack 171Section 3.Q.5.43/7/16 2:23:29 PM by mpattillo
LAB27LAB27-007validatedTestable 0 1 An analyzer supporting the "Query by Tray" Option SHALL be capable of sending a query identifying the position of the specimen in the tray. The only fields populated in the QPD segment SHALL be QPD-1 and QPD-2, QPD-6, QPD-7 and QPD-8. The first four are Mandatory, the latter is Required if Available. QPD-6 identifies the tray and QPD-7 is the position in the tray171Section 3.Q.5.43/7/16 2:23:29 PM by mpattillo
LAB27LAB27-008validatedTestable 0 1 An analyzer supporting the "Query by Isolate" Option SHALL be capable of sending a query identifying an isolate within the primary (parent) specimen. The only fields populated in the QPD segment SHALL be QPD-1 and QPD-2, QPD-3, and QPD-9. All four are Mandatory. QPD-3 identifies the isolate and QPD-9 identifies the primary specimen from which the microorganism was isolated. 171Section 3.Q.5.43/7/16 2:23:29 PM by mpattillo
LAB27LAB27-009validatedTestable 0 1 An analyzer supporting the "Bi-directional Communication" Option SHALL be capable of sending a query identifying the container. The only fields populated in the QPD segment SHALL be QPD-1, QPD-2, and QPD-3 (see Table X.5.1).171Section 3.Q.5.43/7/16 2:23:29 PM by mpattillo