Search Criteria : 17 assertions found for this search Review filtered assertions

Assertion

Applies to

Applied to
Not applied to

Coverage

Covered by
Not covered by
Id scheme
Assertion id
Status
Testable?
#Coverage
#Applies to
Comment
Predicate
Page
Tags
Last changed
Actions
ITI47ITI47-14to be reviewedTestable 0 0 If a number of records is specified in the initialQuantity of the original quantity, and the Patient Demographics Supplier supports the Continuation Option, the Patient Demographics Supplier Actor shall return an incremental response of that number of records when the number of matching records it finds exceeds the number of records specified279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-15to be reviewedTestable 0 0 The Patient Demographics Supplier, which supports the Continuation Option, shall respond in immediate mode.265Section 3.47.4.1.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-16to be reviewedTestable 0 0 The Patient Demographics Supplier, which supports the Continuation Option, shall be able to interpret QueryByParameter.initialQuantity to return successive responses of partial lists of records265Section 3.47.4.1.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-17to be reviewedTestable 0 0 When processing incremental responses, the Patient Demographics Consumer shall request additional responses using the Query Control Act Request Continue/Cancel message (QUQI_MT000001UV01), as described in ITI TF-2b: 3.47.4.3265Section 3.47.4.1.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-26to be reviewedTestable 0 0 A Patient Demographics Consumers need to get another set of matching records to a previously sent Patient Demographics query will trigger the Patient Demographics Query Continuation based on the following HL7 trigger event: Query General Activate Query Continuation (QUQI_TE000003UV01) 277Section 3.47.4.3.12/5/16 12:27:23 PM by aboufahj
ITI47ITI47-27to be reviewedTestable 0 0 The Query continuation is supported by the Query Control Act Request Continue / Cancel (QUQI_MT000001UV01) message. The Patient Demographics Consumer shall generate the continuation message whenever it needs to receive another set of matching records based on the results of a previously sent query.277Section 3.47.4.3.22/5/16 12:27:23 PM by aboufahj
ITI47ITI47-28to be reviewedTestable 0 0 If the Supplier supports the Continuation Option, it shall respond to the continuation request by sending the Patient Registry Find Candidates Response message (PRPA_MT201310), which uses the Application Level Acknowledgement transmission wrapper. This satisfies the requirements of original mode acknowledgment.277Section 3.47.4.3.22/5/16 12:27:23 PM by aboufahj
ITI47ITI47-30to be reviewedTestable 0 0 If a cancellation request is sent by the Patient Demographics Consumer, then the receiver shall respond by sending an Accept Acknowledgement (see ITI TF-2x: Appendix O for the descriptions of the Accept Acknowledgement transmission wrapper277Section 3.47.4.3.22/5/16 12:27:23 PM by aboufahj
ITI47ITI47-31to be reviewedTestable 0 0 The following WSDL naming conventions SHALL apply: query continuation -> "QUQI_IN000003UV01_Message"279Section 3.47.4.3.2.42/5/16 12:27:23 PM by aboufahj
ITI47ITI47-32validatedTestable 0 0 If the Patient Demographics Supplier does not support the Continuation Option and the number of matching records to the original query exceeds the number specified, then, in addition to returning up to that number of records, the Supplier shall return AE (application error) in the Acknowledgement.typeCode (transmission wrapper) and AE (application error) in QueryAck.queryResponseCode (control act wrapper).279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-33to be reviewedTestable 0 0 In the context of the continuation query protocol, the Patient Demographics Supplier shall always populate the resultTotalQuantity, resultCurrentQuantity, and resultRemainingQuantity in the QueryAck class279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-34to be reviewedTestable 0 0 The Patient Demographics Consumer shall indicate a query session cancellation by sending a continuation message, and setting the continuationQuantity attribute to 0, and setting the statusCode to "aborted". 279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-35to be reviewedTestable 0 0 Upon receipt of a cancel message (continuation message, with the continuationQuantity attribute to 0, and the statusCode to "aborted"), the Patient Demographics Supplier shall respond with an Accept Acknowledgement (as described in ITI TF-2x: Appendix O).279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-36to be reviewedTestable 0 0 Sending a query cancellation message is optional. The Patient Demographics Supplier may simply not send any continuation messages once a record has been selected279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-39to be reviewedTestable 0 0 In subsequent query continuation messages, the Patient Demographics Consumer may specify a different number of records to be returned from now on for this query session by populating the continuationQuantity attribute.279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-40to be reviewedTestable 0 0 The consumer may specify from which record the next set of matches should start by populating the startResultNumber attribute279Section 3.47.4.3.32/5/16 12:27:23 PM by aboufahj
ITI47ITI47-8to deleteTestable 0 0 duplicates ITI47-7The response message uses the Application Acknowledgement transmission wrapper, as specified in ITI TF-2x: Appendix O.1.3, and no other acknowledgments are part of this transaction.265Section 3.47.4.1.3.12/5/16 12:27:23 PM by aboufahj