Search Criteria : 23 assertions found for this search Review filtered assertions

Assertion

Applies to

Applied to
Not applied to

Coverage

Covered by
Not covered by
Id scheme
Assertion id
Status
Testable?
#Coverage
#Applies to
Comment
Predicate
Page
Tags
Last changed
Actions
LAB27LAB27-002validatedTestable 2 1 The Analyzer Manager shall reply with the response message (RSP^K11^RSP_K11) containing the acknowledgement of specimen query.169Section 3.Q.53/7/16 2:44:55 PM by aberge
LAB27LAB27-003validatedTestable 1 1 The Analyzer Manager shall then respond with a LAB-28 AWOS Broadcast containing the work for the specimen. 168Section 3.Q.53/7/16 2:45:07 PM by aberge
LAB27LAB27-004validatedTestable 1 1 If the Analyzer Manager has no work for that specimen, it shall send a Negative Query Response by setting ORC-1 to DC in a LAB-28 AWOS Broadcast message.170Section 3.Q.5.33/7/16 2:37:57 PM by aberge
LAB28LAB28-001validatedTestable 1 1 To indicate there is no work to perform (Negative Query Response) for a LAB-27 Query for AWOS, only the MSH, SPM, SAC, and ORC segments SHALL be sent.183Section 3.R.5.13/7/16 2:38:12 PM by aberge
LAB28LAB28-002validatedTestable 2 1 To send an AWOS, the Analyzer Manager SHALL use a OML^O33^OML_O33 message compliant wih table 3.R.5.2-1.180Section 3.R.5.23/7/16 2:45:31 PM by aberge
LAB28LAB28-007validatedTestable 1 0 When the OML^O33 is sent in response to a LAB-27 Query for AWOS for a single specimen, it SHALL only contain the AWOSs or Negative Query Response related to that specimen.185Section 3.R.5.33/7/16 2:38:25 PM by aberge
LAB29LAB29-002validatedTestable 2 1 The Analyzer Manager accepts and registers information, and responds to the Analyzer with the ACK^R22^ACK message. 191Section 3.Y.5.33/7/16 2:45:56 PM by aberge
LAB29LAB29-003validatedTestable 1 1 The Analyzer Manager shall accept unsolicited observations, which are indicated by OBR-2 Placer Order Number populated with a NULL ("") value.191Section 3.Y.5.33/7/16 2:32:53 PM by aberge
LAB29LAB29-004validatedTestable 1 0 The value of ORC-5 across LAB-29 messages shall respect the AWOS status lifecycle.141Figure W.3.7-13/7/16 2:34:16 PM by aberge
LAWLAW-003validatedTestable 1 1 If it appears that the content of the AWOS must be modified or cancelled, the Analyzer Manager shall notify all Analyzers that received the AWOS to cancel the AWOS.33Section X.2.1.13/7/16 2:35:27 PM by aberge
LAWLAW-010validatedTestable 1 1 When the "Pooling on Analyzer" option is supported by the Analyzer and the specimens were not pooled, a pool size "1" shall be returned in OUL^R22^OUL_R22 message.44Section X.2.103/7/16 3:06:51 PM by aberge
LAWLAW-011validatedTestable 2 1 Systems which claim support of the Laboratory Analytical Workflow (LAW) Profile as an Analyzer Manager must implement the Query for AWOS (LAB-27) transaction.47Table X.4-13/7/16 2:43:30 PM by aberge
LAWLAW-012validatedTestable 3 1 Systems which claim support of the Laboratory Analytical Workflow (LAW) Profile as an Analyzer Manager must implement the AWOS Broadcast (LAB-28) transaction.47Table X.4-13/7/16 2:43:31 PM by aberge
LAWLAW-013validatedTestable 3 1 Systems which claim support of the Laboratory Analytical Workflow (LAW) Profile as an Analyzer Manager must implement the AWOS Status Change (LAB-29) transaction.47Table X.4-13/7/16 2:43:32 PM by aberge
LAWLAW-017validatedTestable 1 1 An Analyzer which claims support for the Contributing Subtance option shall send messages compliant with table W.1.3.3-1.72Section W.1.3.33/7/16 3:05:59 PM by aberge
LAWLAW-018validatedTestable 1 1 An Analyzer which claims support for the Dilutions option shall send messages compliant with table W.1.3.4-1.73Section W.1.3.43/7/16 3:06:05 PM by aberge
LAWLAW-020validatedTestable 1 1 An Anayzer which claims support for the Patient Demographics option shall send messages compliant with table W.1.3.5-1.73Section W.1.3.53/7/16 3:06:38 PM by aberge
LAWLAW-026validatedTestable 1 1 An Analyzer which claims support for the AWOS Priority option shall send messages compliant with table W.1.3.9-1.75Section W.1.3.93/7/16 2:50:48 PM by aberge
LAWLAW-029validatedTestable 1 1 An Analyzer which claim supports for the Specimen Details option SHALL send messages compliant with table W.1.3.10-1.76Section W.1.3.103/7/16 3:26:08 PM by aberge
LAWLAW-031validatedTestable 1 1 An Analyzer which claims support for the Mass Spectrometry option shall send messages compliant with table W.1.3.12-1.77Section W.1.3.12-13/7/16 3:06:27 PM by aberge