Search Criteria : 19 assertions found for this search Review filtered assertions

Assertion

Applies to

Applied to
Not applied to

Coverage

Covered by
Not covered by
Id scheme
Assertion id
Status
Testable?
#Coverage
#Applies to
Comment
Predicate
Page
Tags
Last changed
Actions
RAD68RAD68-003reviewedTestable 2 1 The Imaging Document Source creates a manifest that describes and collects references to DICOM SOP instances that are intended for sharing. The manifest, a Key Object Selection (KOS) Document Instance, is the actual document provided to the Document Repository and registered at the Document Registry. 173Section 4.68.4.1.2.12/13/17 11:47:13 AM by aberge
RAD68RAD68-004reviewedTestable 2 1 the structure of the Request message between the Document Source and the Document Repository is an MTOM/ XOP formatted message.173Section 4.68.4.1.2.12/13/17 11:47:15 AM by aberge
RAD68RAD68-005reviewedTestable 2 1 The KOS Document Instance is encoded in the Request message as a DICOM Part 10 File format having a MIME type of “application/dicom”.173Section 4.68.4.1.2.12/13/17 11:47:17 AM by aberge
RAD68RAD68-006reviewedTestable 0 1 The Imaging Document Source shall ensure that the DICOM SOP Instances referenced from within the manifest are available to be retrieved. If the Imaging Document Source makes one or more SOP Instances unavailable that are referenced in a published manifest, then it shall submit a new manifest as a replacement for the published manifest already in the Document Repository and Document Registry (see IHE ITI TF-3:4.2.2.2 “Document Relationships”). The new manifest shall have the updated list of DICOM SOP Instances with the unavailable instances removed. 173Section 4.68.4.1.2.11/18/17 4:17:13 PM by jdramou
RAD68RAD68-007reviewedTestable 0 1 If the Imaging Document Source makes all referenced DICOM SOP Instances unavailable in a published manifest, then it shall deprecate the published manifest without any replacement (IHE ITI XDS Metadata Update Supplement). 174Section 4.68.4.1.2.11/18/17 4:17:13 PM by jdramou
RAD68RAD68-008reviewedTestable 2 1 The references to the DICOM SOP Instances shall be included in the Current Requested Procedure Evidence Sequence (0040,A375) attribute of the KOS Manifest Document. 174Section 4.68.4.1.2.1.12/13/17 11:47:20 AM by aberge
RAD68RAD68-009reviewedTestable 2 1 The Imaging Document Source shall support these attributes in Current Requested Procedure Evidence Sequence (0040,A375), which are represented in the Hierarchical SOP Instance Reference Macro:Study Instance UID (0020,000D)Referenced Series Sequence (0008,1115)Series Instance UID (0020,000E)Referenced SOP Sequence (0008,1199)Referenced SOP Class UID (0008,1150)Referenced SOP Instance UID (0008,1155)174Section 4.68.4.1.2.1.12/13/17 11:47:22 AM by aberge
RAD68RAD68-010reviewedTestable 2 1 The Imaging Document Source shall support these attributes in Current Requested Procedure Evidence Sequence (0040,A375), which are represented in the Hierarchical SOP Instance Reference Macro, using its own identification:Retrieve AE Title (0008,0054)Retrieve Location UID (0040,E011)174Section 4.68.4.1.2.1.12/13/17 11:47:24 AM by aberge
RAD68RAD68-011reviewedTestable 2 1 The Imaging Document Source may support these attributes in Current Requested Procedure Evidence Sequence (0040,A375), which are represented in the Hierarchical SOP Instance Reference Macro:Storage Media File-Set ID (0088,0130)Storage Media File-Set UID (0088,0140)174Section 4.68.4.1.2.1.12/13/17 11:47:28 AM by aberge
RAD68RAD68-022reviewedTestable 2 1 XDSDocumentEntry Attribute: formatCodeShall use “1.2.840.10008.5.1.4.1.1.88.59” (DICOM KOS SOP Class UID) as the Format Code Value and “1.2.840.10008.2.6.1” (DICOM UID Registry UID) as the Format Coding Scheme OID 177Section 4.68.4.1.2.3.22/13/17 11:47:48 AM by aberge
RAD68RAD68-026reviewedTestable 2 1 XDSDocumentEntry Attribute: mimeTypeShall be “application/dicom”177Section 4.68.4.1.2.3.22/13/17 11:47:50 AM by aberge
RAD68RAD68-037reviewedTestable 2 1 XDSDocumentEntry Attribute: uniqueIdShall be the same as the SOP Instance UID of the corresponding DICOM KOS object. In the event that any information in the manifest changes and it needs to be resubmitted from the Imaging Document Source to the Document Repository, the Imaging Document Source shall generate a new SOP Instance UID for the DICOM KOS object.179Section 4.68.4.1.2.3.22/13/17 11:48:15 AM by aberge
RAD68RAD68-039reviewedTestable 2 1 The Extended Composite ID shall be mapped from DICOM elements to the HL7 CX data type as described in RAD TF-3 4.68.4.1.2.3.3.1 and table 4.68.4.1.2.3-2 CX Data Type Mapping.180Section 4.68.4.1.2.3.3.12/13/17 11:48:17 AM by aberge
RAD68RAD68-040reviewedTestable 2 1 HL7 DTM Data Type can be represented as YYYY[MM[DD[HH[MM[SS]]]]], transformed from DICOM elements of VR DA (format: YYYYMMDD) and TM (format: HHMMSS.fraction). 181Section 4.68.4.1.2.3.3.22/13/17 11:48:19 AM by aberge
RAD68RAD68-041reviewedTestable 2 1 HL7 XCN data types for person ID and name shall be representing using data from the DICOM elements, transcoded as described in RAD TF-3 4.68.4.1.2.3.3.3 and Table 4.68.4.1.2.3-3.181Section 4.68.4.1.2.3.3.32/13/17 11:48:25 AM by aberge
RAD68RAD68-042reviewedTestable 2 1 HL7 XON data types for organization ID and name shall be represented using data from the DICOM elements as described in RAD TF-3 4.68.4.1.2.3.3.4 and table 4.68.4.1.2.3-4.182Section 4.68.4.1.2.3.3.42/13/17 11:48:32 AM by aberge
RAD68RAD68-043reviewedTestable 2 1 HL7 CXi data types for accession numbers shall be represented using data from the DICOM elements as described in RAD TF-3 4.68.4.1.2.3.3.5 and table 4.68.4.1.2.3-50Section 4.68.4.1.2.3.3.52/13/17 11:48:36 AM by aberge
XDSIXDSI-010reviewedTestable 7 1 If the Imaging Document Source supports the Set of DICOM Instances option, it shall support all of the following transactions:+ [RAD-16] Retrieve Images+ [RAD-17] Retrieve Presentation States+ [RAD-27] Retrieve Reports+ [RAD-31] Retrieve Key Image Note+ [RAD-45] Retrieve Evidence Documents+ [RAD-55] WADO Retrieve+ [RAD-69] Retrieve Imaging Document Set203Section 18.12/13/17 10:51:15 AM by xfrancois
XDSIXDSI-011reviewedTestable 9 1 This option requires the Imaging Document Source to create a DICOM manifest that references DICOM instances, and to provide and register this document to the Document Repository. The Imaging Document Source is required to ensure that the referenced images from within a published manifest are available to be retrieved. For details of the transaction affected by this option, refer to RAD TF-3: 4.68.4.1.2.1.204Section 18.2.12/13/17 10:51:17 AM by xfrancois