Assertion

AssertionId
ITI47-32 Testable
predicate
If the Patient Demographics Supplier does not support the Continuation Option and the number of matching records to the original query exceeds the number specified, then, in addition to returning up to that number of records, the Supplier shall return AE (application error) in the Acknowledgement.typeCode (transmission wrapper) and AE (application error) in QueryAck.queryResponseCode (control act wrapper).
Prescription level
Mandatory / Required / Shall
Page
279
Section
3.47.4.3.3
Status
validated
Last changed
2/5/16 12:27:23 PM by aboufahj
Comment

Applies to

Actors

AIPOs

Audit Messages

Integration Profiles

Transactions

Standards

Covered by

Tests

Test Steps

Rules

MBV

Covered by (Deprecated)

Tests

Test Steps

Rules

Document name
Provenance
Revision
Action
IHE IT Infrastructure Technical Framework - Volume 2bIHE12