Assertion

AssertionId
RAD55-026 Testable
predicate
Shall return HTTP response code 404 (Not Found) if the Imaging Document Consumer requested retrieval of rejected DICOM SOP Instance(s) referenced in that KOS. Rejected SOP Instances are marked with Document Title valued (113001, DCM, “Rejected for Quality Reasons”), (113037, 2855 DCM, “Rejected for Patient Safety Reasons”), (113038, DCM, “Incorrect Modality Worklist Entry) or (113039, DCM, “Data Retention Policy Expired")
Prescription level
Mandatory / Required / Shall
Page
126
Section
4.55.4.1.3
Status
reviewed
Last changed
1/18/17 5:57:11 PM by jdramou
Comment

Applies to

Audit Messages

Integration Profiles

Transactions

Standards

Covered by

Tests

Test Steps

Rules

MBV

Covered by (Deprecated)

Tests

Test Steps

Rules

Document name
Provenance
Revision
Action
IHE Radiology Technical Framework - Volume 3IHE14.0